Pengaruh Faktor Eksposi Terhadap Respon Detektor Isian Gas Pada Surveymeter Berbasis IoT

Authors

  • Chandra Kusuma Sekolah Tinggi Ilmu Kesehatan Semarang
  • Diah Rahayu Ningtias Sekolah Tinggi Ilmu Kesehatan Semarang

DOI:

https://doi.org/10.61132/mars.v2i1.58

Keywords:

Surveymeter, Geiger Muller Detector, Exposure Factor, Radiation Exposure Dose, Database

Abstract

A surveymeter is a measuring instrument that functions to detect radiation exposure doses, which uses a Geiger Muller gas filled detector with the initial unit of sievert converted to microsievert (μSv/hour). In this research, we fabricated an IoT-based surveymeter and tested the response of the gas fill detector used to changes in exposure factors. Before collecting data, it is mandatory to set parameters on the control panel to determine the radiation exposure dose to be measured. Measurements are carried out on a mobile X-Ray with parameter settings including tube voltage (kV), tube current (mA), and exposure time (s). From the results of research that the Geiger Muller gas filled detector responds to the radiation exposure dose that has been determined on the control panel and fired by mobile X-Ray, the results detected by the detector will be displayed in the application in the form of Counts Per Minute (CPM), µSv/h, + /- and data can be stored in the database. The higher the tube current value given, the smaller the radiation dose value obtained. In other words, the gas fill detector responds with a dose value that is directly proportional to the X-ray tube voltage value and inversely proportional to the X-ray tube current value.

References

Anggara, A. D. (2020). Pengaruh Faktor Eksposi Digital Radiography (DR) Terhadap Nilai Kontras Pada Citra Phantom Sebagai Organ Tiruan. Jurnal Fisika, 10(2). https://doi.org/10.15294/jf.v10i2.25513

Babalola, T. E., Babalola, A. D., & Olokun, M. S. (2022). Development of an ESP-32 Microkontroller Based Weather Reporting Device. Journal of Engineering Research and Reports. https://doi.org/10.9734/jerr/2022/v22i1117577

Bonczyk, M., Grygier, A., & Skubacz, K. (2022). “Quantum Pendants” - the measurement of exposure to enhanced natural radioactivity. Measurement: Journal of the International Measurement Confederation, 196. https://doi.org/10.1016/j.measurement.2022.111212

Cho, Y. I., Shin, S. H., & Kim, J. H. (2020). Dose assessment and shielding analysis of the working environments for non-destructive testing. Journal of Instrumentation, 15(6). https://doi.org/10.1088/1748-0221/15/06/P06012

Diah, Rahayu Ningtias; Muhammad, R., Bayu, W., Josepa ND, S., & Rodhotul, M. (2023). IDENTIFIKASI PAPARAN RADIASI X-RAY UNTUK KESELAMATAN RADIASI MENGGUNAKAN RANDOM FOREST CLASSIFICATION. 8, 1–13.

Dickson, K. (2020). Pengertian LED (Light Emitting Diode) dan Cara KerjanyaNo Title. 2020.

Fachrully Septiano, A., Rahayu Ningias, D., Susilo, S., Maulana, I., & Anggraeny, C. (2023). Pengembangan Surveymeter Radiasi Berbasis Arduino Internet of Things (IoT) Sebagai Penunjang Keselamatan Radiasi. Jurnal Pengawasan Tenaga Nuklir, 3(2), 59–64. https://doi.org/10.53862/jupeten.v3i2.010

Faradina Pratiwi, R., Sundari Pulungan, E., & Andini, D. (2023). PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI PADA PEMERIKSAAN THORAX. JRI (Jurnal Radiografer Indonesia), 6(1). https://doi.org/10.55451/jri.v6i1.173

Hidayatullah, S. S. (2020). Pengertian Buzzer Elektronika Beserta Fungsi Dan Prinsip Kerjanya. In Belajaronline.Net.

Hilyana, F. S. (2017). Penentuan Tegangan Operasional Pada Detektor Geiger Muller Dengan Perbedaan Jari-Jari Window Detektor. Simetris: Jurnal Teknik Mesin, Elektro Dan Ilmu Komputer, 8(1), 393–398. https://doi.org/10.24176/simet.v8i1.897

Hounsou, F. T. M., Sina, H., Avocefohoun, A. S., Aina, P., Gbaguidi, A. B., Amoussou-Guenou, K. M., & Baba-Moussa, L. (2020). Radiological Quality and Dangerousness of Ferrous and Non-ferrous Metals Waste in Cotonou (Benin). Asian Journal of Environment & Ecology. https://doi.org/10.9734/ajee/2020/v12i230154

Japeri, J., Saifi, S., Persadha, G., & Zaini, M. (2020). Calculation Of Radiation Dosage Value In Patients Based On Android Application. Jurnal Kajian Ilmiah Kesehatan Dan Teknologi, 2(2). https://doi.org/10.52674/jkikt.v2i2.31

Jaya, G. W., Sutanto, H., Hidayanto, E., & Saraswati, G. P. (2020). Progressive Physics Journal. Progressive Physics Journal, 1(2017), 15–19.

Ketty Siti Salamah, Trie Maya Kadarina, & Zendi Iklima. (2020). Pengenalan Mit Inventor Untuk Siswa/I Di WilayahKembangan Utara. Jurnal Abdi Masyarakat (JAM), 5–9.

Kho, D. (2022). Pengertian Baterai dan Jenis-jenisnya. Teknikelektronika.Com.

Ningtias, D. R., Wahyudi, B., & Harsoyo, I. T. (2022). JITE ( Journal of Informatics and Telecommunication Engineering ) Comparative Test of the Effect of X-Ray Tube Current Analysis and Exposure Time on CR ( Computed Radiography ) Image Quality. 6(July), 267–275.

Rokhmat, A. R. S. S. R. P. H., & Roni Cahya, C. F. D. I. (2023). KOMPARASI PERFORMA MONITOR RADIASI GAMMA DALAM PEMANTAUAN RADIASI REAL–TIME Rokhmat. 29(2), 71–86.

Saputra, R. D., & Oktavia, V. Y. (2020). Pengukuran Cacah Radiasi Nuklir dengan menggunakan Geigen Muller di Laboratorium Fisika Modern Universitas Negeri Malang. 5.

Sari, O. P., Mareta, S., & Nisa, C. (2023). ANALISA KARAKTERISTIK MAHASISWA DIII RADIOLOGI TERHADAP PENGETAHUAN PROTEKSI RADIASI PADA IMPLEMENTASI KESELAMATAN KERJA SAAT PRAKTIKUM/MAGANG. 4, 6889–6895.

Utami, N. W. M. S., Ni Nyoman, R., & I Putu Eka, J. (2021). Pengaruh Kombinasi Arus Tabung Sinar-X dan Waktu Eksposi Terhadap Contrast to Noise Ratio (CNR) dengan menggunakan Computed Radiography. BULETIN FISIKA, 23(1). https://doi.org/10.24843/bf.2022.v23.i01.p04

Wang, P., Tang, X. Bin, Gong, P., Huang, X., Wen, L. S., Han, Z. Y., & He, J. P. (2018). Design of a portable dose rate detector based on a double Geiger–Mueller counter. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 879(September 2016), 147–152. https://doi.org/10.1016/j.nima.2017.07.061

Downloads

Published

2024-02-13

How to Cite

Chandra Kusuma, & Diah Rahayu Ningtias. (2024). Pengaruh Faktor Eksposi Terhadap Respon Detektor Isian Gas Pada Surveymeter Berbasis IoT. Mars : Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer, 2(1), 33–45. https://doi.org/10.61132/mars.v2i1.58

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.