Perbandingan Efisiensi Teknik PWM dan VFD dalam Pengendalian Motor Listrik

Authors

  • Moh. Nizar Khamdun Universitas Islam Sultan Agung

DOI:

https://doi.org/10.61132/merkurius.v3i2.740

Keywords:

energy, efficiency, electric-motor, PWM, VFD

Abstract

This study discusses the comparison of efficiency between Pulse Width Modulation (PWM) and Variable Frequency Drive (VFD) techniques in electric motor control. The background of this research is based on the importance of energy efficiency in industrial applications using electric motors. The aim of this study is to identify the advantages and disadvantages of each method in the context of energy savings and motor performance. The method used is a quasi-experimental design, where both techniques are tested on the same three-phase induction motor to compare power consumption and operational efficiency. The findings indicate that the use of VFD is significantly more efficient in reducing power consumption compared to PWM and provides better torque stability in the motor. The implications of this research suggest that the application of VFD can enhance energy efficiency and reduce operational costs, which is crucial for industries. This study is expected to serve as a reference for further development in electric motor control technology.

References

Ashabullah, M. H., Suratno, & Yadie, E. (2024). Analisis kinerja dan harmonik motor induksi 3 fasa dengan variable frequency drive pada boiler feed water pump di PT. Cahaya Fajar Kaltim menggunakan ETAP. JTE UNIBA, 9(1), 502-510. E/P-ISSN: 2549-0842/2528-6498.

Atul, P. (2012). PWM based automatic closed loop speed control of DC motor. International Journal of Engineering Trends and Technology, 3(2).

Bakibillah, A. S. M., Rahman, N., & Zaman, U. A. (2014). Closed loop speed control of a DC motor using a microcontroller and PWM technique. International Journal of Computer Applications, 108(14), 15-18.

Fatma, M. W., & Hamid, M. I. (2019). PWM speed control of DC permanent magnet motor using a PIC18F4550 microcontroller. Conference on Innovation in Technology and Engineering Science, IOP Publishing. https://doi.org/10.1088/1757-899X/602/1/012017

Ganesh, V., Senthilmurugan, S., Prabhu, A., & Krishna, A. V. M. (2020). VFD based performance analysis of the pump. International Journal of Recent Technology and Engineering (IJRTE), 8(6), 2896-2900. https://doi.org/10.35940/ijrte.F8144.038620

Gonzalez, P., Buigues, G., & Mazon, A. J. (2023). Noise in electric motors: A comprehensive review. Energies, 16(14), 5311. https://doi.org/10.3390/en16145311

Islam, M. S., & Tripathi, V. K. (2016). A study of D.C motor speed control through pulse width modulation implemented by MATLAB simulation. International Journal of Advanced Research in Computer and Communication Engineering, 5(6), 219-223.

Katsambe, C. T., Luckose, V., & Shahabuddin, N. S. (2017). Effect of pulse width modulation on DC motor speed. International Journal of Students’ Research In Technology & Management, 5(2), 42-45. https://doi.org/10.18510/ijsrtm.2017.522

Khan, M. R. (2015). Speed control of DC motor under varying load using PID controller. International Journal of Engineering (IJE), 9(3).

Klee, S. (2005). Development of a motor speed control system using MATLAB and Simulink. MSc. Thesis, Orlando, Florida.

Ko, J.-S., Huh, J.-H., & Kim, J.-C. (2019). Improvement of energy efficiency and control performance of cooling system fan applied to Industry 4.0 data center. Electronics, 8(5), 582. https://doi.org/10.3390/electronics8050582

Koti Babu, R., Devi Sri Manju, P., & Manikanta Sai, N. B. (2021). Speed control of DC motor using PWM technique. IRE Journals, 4(11), 217-222.

Oku, E. N., Effiong, E. E., Ekpenyong, O., & Bernard, P. N. (2024). Modeling of DC motor PWM control drive for adjustable speed applications. World Journal of Engineering Research and Technology, 10(12), 180-189. ISSN 2454-695X.

Pawar, H. P., Chavan, N. S., Shinde, A. B., & Chavan, Y. S. (2015). Speed control of induction motor using PWM technique. International Journal of Engineering Research & Technology (IJERT), 4(04), 174-177. ISSN: 2278-0181.

Sarbu, I., & Valea, E. S. (2015). Energy savings potential for pumping water in district heating stations. Sustainability, 7(5), 5705-5719. https://doi.org/10.3390/su7055705

Shah, D. A., Sanas, P. G., Mahajan, A. O., Jamdade, M. A., & Gulame, M. B. (2015). Literature review on variable frequency drive. International Journal for Scientific Research & Development, 3(08), 690-691. ISSN (online): 2321-0613.

Sumarta, P., & Aini, Z. (2024). Desain penggunaan variable frequency drive (VFD) pada starting-up motor induksi 3 fasa menggunakan metode sinusoidal pulse-width modulation (SPWM). Jurnal AL-AZHAR INDONESIA SERI SAINS DAN TEKNOLOGI, 9(3), 317-329. https://doi.org/10.36722/sst.v9i3.2910

Yusuf, S. D., Agada, C. U., Loko, A. Z., & Lumbi, L. W. (2020). Construction of a pulse width modulation (PWM) DC motor controller. SSRG International Journal of Electrical and Electronics Engineering, 7(4), 9-14.

Downloads

Published

2025-03-04

How to Cite

Moh. Nizar Khamdun. (2025). Perbandingan Efisiensi Teknik PWM dan VFD dalam Pengendalian Motor Listrik. Merkurius : Jurnal Riset Sistem Informasi Dan Teknik Informatika, 3(2), 154–172. https://doi.org/10.61132/merkurius.v3i2.740