Analysis Of The Efficiency Of Using A 3-Phase Induction Motor As Pump Drive At PDAM Surya Sembada Surabaya

Authors

  • Dhamar Bagaskara University of 17 August 1945 Surabaya
  • Praise Slamet University of 17 August 1945 Surabaya

DOI:

https://doi.org/10.61132/uranus.v2i3.203

Keywords:

Three Phase induction motor, Efficiency, Voltage, Performance, Power Quality

Abstract

An induction motor is an electrical device that converts electrical energy into energy. Electric machines use various types of drives, such as water pumps. Applications in transportation equipment, household equipment transportation tools, and large-scale industry. for several reasons. To get the best performance, the induction motor supply must be checked for quality problems, such as changes to the motor power supply. This research analyzes and measures the effect of three-phase induction motors using different power sources from 380 Volts. The motor used is a 3 phase motor at PDAM Suraya Sembada which is located on Jl. Ngagel Tirto V No. 53, Ngagelrejo, district. Wonokromo, Surabaya, East Java. In completing this research, we used the method of mathematical calculating formulas for validation and comparison. The data taken were current, rpm (speed), voltage, cosphi. This research found that a threephase induction motor at 379 Volts had an effect of 84.27%, while the overall average in this study had an average efficiency value of 73%-75

References

Aryza, S., Irwanto, M., Lubis, Z., Siahaan, AP, Rahim, R., & Furqan, M. (2018). a Novelty Design of Minimization of Electrical Losses in Vector Controlled Induction Machine Drive.IOP Conference Series: Materials Science and Engineering, 300(1), 12-67.

Ghazali, RA (2011). Moderate Induction Motor Efficiency Calculation Method Operate.Electrical Engineering Study Program, Faculty of Engineering, University of Indonesia.

Hakim, A. (2020). Analysis of the Effect of Unbalanced Current on Motor Work 3 Phase Induction.Electrical Engineering Study Program, Faculty of Engineering, Muhammadiyah University, North Sumatra.

Hamdani, H., Tharo, Z., & Anisah, S. (2019). Comparison of Plant Performance Solar Electricity Between Mountain Areas and Coastal Areas. UISU National Engineering Seminar (Semnastek), 2(1), 190-195.

Pratiwi, ND (2020). Voltage and Frequency Instability Analysis

Microhydro Power Plant (Case Study of PLTMH Sokokembang, Pekalongan Regency.Malang State University Electrical Engineering Education Thesis.

Putri, M., Wibowo, P., Aryza, S., Utama, S., &Russiadi, AP (2018). an Implementation of a Filter Design Passive lC in Reducing a Current Harmonics. International Journal of Civil Engineering and Technology, 9(7), 867-873.

Tarigan, AD, & Pulungan, R. (2018). The Effect of Using Unbalanced Loads

Regarding the Age of RELE Electrical Equipment (Electrical and Energy Engineering).

Journal of Electrical Engineering, 1(1), 10-15.

Published

2024-07-04

How to Cite

Dhamar Bagaskara, & Praise Slamet. (2024). Analysis Of The Efficiency Of Using A 3-Phase Induction Motor As Pump Drive At PDAM Surya Sembada Surabaya. Uranus : Jurnal Ilmiah Teknik Elektro, Sains Dan Informatika, 2(3), 73–82. https://doi.org/10.61132/uranus.v2i3.203

Similar Articles

1 2 3 4 5 6 > >> 

You may also start an advanced similarity search for this article.