Penggantian Minyak OLTC Trafo 2 150 kV di Gardu Induk Rangkasbitung Baru PLN ULTG Rangkasbitung

Authors

  • Fadilah Fadilah Universitas Sultan Ageng Tirtayasa
  • Bagus Dwicahyono Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.61132/mars.v4i1.1420

Keywords:

Maintenance, Oil, OLTC, Reliability, Substation

Abstract

PLN (Persero) is the state-owned company responsible for supplying electrical energy in Indonesia and plays a crucial role in ensuring the reliability and continuity of power distribution. Therefore, all electrical equipment, particularly power transformers, must be maintained in safe and reliable operating conditions. Transformers function to change voltage levels from high to low or vice versa and are essential components in the electric power distribution system. One important transformer component that requires periodic maintenance is the On Load Tap Changer (OLTC). To maintain transformer performance and extend its service life, routine maintenance activities such as OLTC oil replacement are necessary. PT. PLN (Persero) ULTG Rangkasbitung conducts regular OLTC oil replacement twice a year as part of its preventive maintenance program. Transformer oil serves as both an insulating medium and a cooling agent; therefore, its condition greatly affects transformer reliability and operational safety. Degraded oil quality can cause insulation failure and reduce transformer efficiency. This study aims to describe the procedure and implementation of On Load Tap Changer oil replacement at the transformer substation of PT. PLN (Persero) ULTG Rangkasbitung. The research method used is field research, carried out through direct observation and interviews with maintenance personnel. The results of this study are expected to provide a clear understanding of the OLTC oil replacement process, support proper maintenance practices, and emphasize the importance of transformer maintenance in ensuring the reliability and sustainability of the electric power system.

References

Arismunandar, A. (2004). Teknik tegangan tinggi. Pradnya Paramita.

Blackburn, J. L., & Domin, T. J. (2014). Protective relaying: Principles and applications. CRC Press.

Djufri, I. (2022). Transformator. Deepublish.

IEC. (2013). Mineral insulating oils in electrical equipment – Supervision and maintenance (IEC 60422). IEC.

IEC. (2020). Fluids for electrotechnical applications – Mineral insulating oils (IEC 60296). IEC.

IEEE. (2015). Guide for acceptance and maintenance of insulating oil in equipment (IEEE Std C57.106-2015). IEEE.

Kadir, A. (2013). Transmisi tenaga listrik. Universitas Indonesia Press.

Naidu, M. S., & Kamaraju, V. (2010). High voltage engineering. McGraw-Hill.

Nugroho, A., & Prasetyo, B. (2020). Pemeliharaan OLTC pada transformator tenaga 150 kV. Jurnal Teknik Elektro, 12(1), 45–52. https://doi.org/10.26618/jte.v1i2.2380

PLN. (2014). Buku pedoman pemeliharaan transformator tenaga. PT. PLN (Persero).

PLN. (2014). Buku pemeliharaan reaktor. PT. PLN (Persero).

PLN. (2016). SPLN D3.002-1:2016. Minyak isolasi untuk transformator dan peralatan listrik. PT. PLN (Persero).

PLN. (2019). Standar pemeliharaan peralatan gardu induk. PT. PLN (Persero).

Stevenson, W. D. (1982). Elements of power system analysis. McGraw-Hill.

Suryono. (2018). Analisis kualitas minyak transformator daya. Jurnal Energi dan Kelistrikan, 10(2), 85–92.